; !GCI0000.CFG FOR EISA SYSTEM BOARD
;
; VER1.0
;GATEWAY COMMUNICATIONS, INC.
;
BOARD
ID="GCI0000" ; ISA Gateway AT Ethernet Interface Card Rev 00
NAME="G/Ethernet AT" ; Product Name
MFR="Gateway Comm., Inc." ; Manufacturere Name
CATEGORY="NET" ; Category = Network Board
SLOT=ISA16 ; Uses ISA 16 bit slot
LENGTH=170 ; Length of board in Millimeters
READID=YES ; Board ID can be read
;
COMMENTS="Gateway Communications' G/Ethernet 16 bit AT Adapter\n
If configuring the card for use with NetWare(r),\n
the IRQ lines and I/O port addresses ARE linked.\n
See the installation manual for details.\n\n
Remote Boot is automatically initiated if...\n
there is no disk drive, and, a BOOTROM is in its socket."
;
SWITCH(1)=8 ; 8 position switch block
NAME="SW1: IO Adr/BOOTROM" ; Switches 1-4 set I/O address, switches 5 & 6
; set Boot Prom Memory address switches 7 & 8
; are not used and must be OFF
STYPE=DIP ; Switch Style = DIP SWITCH
VERTICAL=YES ; Switch Block is positioned vertically
REVERSE=YES ; Switches number from bottom to top
LABEL=LOC(1-8)"SW1-1""SW1-2""SW1-3""SW1-4""SW1-5""SW1-6""SW1-7""SW1-8"
INITVAL=LOC(7-8)00 ; Switches 7 & 8 must be OFF
FACTORY=LOC(1-8)10110000 ; Factory default = I/O 2a0
COMMENTS="\t Default I/O port address is 2A0h; that is,\n
\t switches 1, 3, & 4 ON, the rest OFF.\n
\t Default BOOTROM address is 0CC0000; that is\n
\t switches 5 $ 6 OFF\n
\t Remote Boot is automatically initiated\n
\t if... there is no disk drive, and, a\n
\t BOOTROM is in its socket.\n
\t Switches 7 & 8 must be OFF.\n
\t "
;
JUMPER(1)=6 ; 6 position jumper block
NAME="JP2: IRQ selection" ; Sets Board IRQ
JTYPE=PAIRED ; Standard Berg type DIP Header
VERTICAL=NO ; Jumper block is positioned horizontally
REVERSE=YES ; Positions number from left to right
LABEL=LOC(1-6)"IRQ2""IRQ3""IRQ4""IRQ5""IRQ6""IRQ7"
FACTORY=LOC(1-6)010000 ; Default setting is IRQ3
COMMENTS="\t Only 1 jumper may be set at one time.\n
\t Default is IRQ3; that is, jumper loc. 2.\n
\t "
;
JUMPER(2)=4 ; 4 position jumper block
NAME="JP4: Cable Type" ; Selects AUI Port or BNC connector
JTYPE=TRIPOLE ; Standard Berg Type Tripole Header
VERTICAL=NO ; Jumper is positioned horizontally
REVERSE=YES ; Positions number from left to right
FACTORY=LOC(1-4)1111 ; Default is Thin Ethernet (BNC Connector)
COMMENTS="\t Thin-wire is default, use BNC connector.\n
\t All 4 jumpers must be UP.\n
\t Thick-wire, use AUI connector.\n
\t All 4 jumpers must be DOWN.\n
\t "
HELP="\t Thin-wire is default, use BNC connector.\n
\t All 4 jumpers must be UP.\n
\t Thick-wire, use AUI connector.\n
\t All 4 jumpers must be DOWN."
;
FUNCTION="G/Ethernet Adapter for AT bus."
CHOICE="G/Ethernet 16 bit AT Adapter"
LINK
IRQ=3|2|4|5|6|7
INIT=JUMPER(1)LOC(1-6)
010000|100000|001000|000100|000010|000001
;
LINK
PORT=2A0h-2BFh|280h-29Fh|2C0h-2DFh|2E0h-2FFh|300h-31Fh|
320h-33Fh|340h-35Fh|360h-37Fh
INIT=SWITCH(1)LOC(1-4)
1011|1111|1101|1001|1110|1010|1100|1000
;
FUNCTION="Ether Thin/Thick Cable Type"
COMMENTS="\t Thin/Thick Cable Selection:\n
\t Thin-cable is default, use BNC connector.\n
\t All 4 jumpers must be UP.\n
\t Thick-cable, use AUI connector.\n
\t All 4 jumpers must be DOWN.\n
\t "
HELP="\t Thin-wire is default, use BNC connector.\n
\t All 4 jumpers must be UP.\n
\t Thick-wire, use AUI connector.\n
\t All 4 jumpers must be DOWN."
CHOICE="Thin-Wire (BNC) Connection"
FREE
INIT=JUMPER(2)LOC(1-4)1111
CHOICE="Thick-Wire (AUI) Connection"
FREE
INIT=JUMPER(2)LOC(1-4)0000
;
FUNCTION="Remote BOOTROM Address"
COMMENTS="\t Remote Boot is automatically initiated\n
\t if... there is no disk drive, and, a\n
\t BOOTROM is in its socket.\n
\t "
CHOICE="BOOTROM Address"
LINK
MEMORY=16K
ADDRESS=0CC000h|0C0000h|0C4000h|0C8000h
WRITABLE=NO
MEMTYPE=OTHER
INIT=SWITCH(1)LOC(5-6)00|11|01|10
;
; End of board